Fire Safety Store North West / Product guidance

Fire door installation guide.

Guidance for handling, storing and arranging the installation of a fire door or doorset supplied by us. Keep this page with your order documents and share it with your installer.

Your document

View or download the installation guide

Keep a copy with the product paperwork. This PDF contains illustrated fitting details for the Falcon Panel Products Stredor CE-marked doorset system identified in the document.

FD30 & FD60 doorset installation guide

Seven-page PDF covering preparation, storage, frame positioning and fixing, sealing to the structural opening and handling recommendations for the system identified in the document.

Open installation PDF ↗
Check applicability: This PDF describes the Falcon Panel Products Stredor system and supplements the relevant manufacturer's instructions. Some measurements and methods are specific to that system. Confirm that the document supplied with your order covers your actual door or doorset. If it does not, request the applicable instructions before installation.
Installation process / overview

What to check at each stage

This overview helps customers and installers plan the work. Follow the complete instructions for the exact supplied product.

01 / BEFORE DELIVERY

Confirm the specification

Check the door schedule, rating, dimensions, handing, frame, glazing and compatible hardware against the order and the intended opening. Make the correct instructions available to the installer.

02 / ON ARRIVAL

Inspect and store correctly

Check the product and packaging promptly and report visible damage. Store as instructed, away from damp and weather. Avoid installing timber doorsets while wet trades are still drying.

03 / BEFORE FITTING

Check the opening and components

The installer should check that the supporting construction, opening, frame and specified components suit the tested or assessed assembly. Do not substitute parts without evidence permitting the change.

04 / DURING INSTALLATION

Follow the tested detail

Frame position, fixings, packers, operating gaps and perimeter fire stopping must follow the instructions for the exact product. The PDF's Stredor dimensions are not universal.

05 / COMPLETION

Check operation and records

Have the installer check alignment, closing and latching, seals, glazing and fitted ironmongery. Keep the product identification, instructions and completion records.

06 / THROUGHOUT USE

Keep the door effective

Do not wedge it open or make unapproved alterations. Arrange the ongoing checks and maintenance appropriate to the building and its requirements.

Choosing a fitter

How to find the right fire door installer

Fire Safety Store North West supplies products online. We do not fit, inspect or certify installed doors. Choose an installer who can demonstrate competence for the particular product, building and work.

Explore BM TRADA's installation scheme ↗
  • Ask about relevant experience with the fire door or doorset construction and type of opening.
  • Check current certification where claimed. Verify the company and the scope of its certification directly with the certification body.
  • Provide the full document pack before quoting: door schedule, manufacturer instructions, supporting evidence, frame and hardware details.
  • Request a written scope and handover. Confirm who supplies compatible parts, handles perimeter fire stopping and records the completed installation.
  • Ask how unexpected site conditions will be handled. The installer should seek the relevant manufacturer's or designer's guidance instead of improvising beyond the approved detail.
Further reading

Useful resources

Independent information to support product selection and installation planning.

Quick answers

Installation questions

Can I use this PDF for every fire door sold on the website?

No. The PDF identifies a specific Falcon Panel Products Stredor doorset system. Use it only where it applies to the delivered product, alongside its current manufacturer instructions and supporting evidence. Ask us for the relevant product documents if there is a mismatch.

Does buying a fire-rated leaf make an installed opening compliant?

No. Performance depends on the specified complete assembly, compatible parts, supporting structure, correct installation and ongoing condition. A leaf alone does not establish the performance of the installed opening.

Can you book an installer?

We do not provide installation services or book installers. Use the checks above and verify any claimed certification directly with the scheme provider before appointing a company.

What if the opening differs from the guide?

Do not guess a packing or sealing method. The installer should check the applicable product evidence and obtain guidance from the manufacturer, designer or another appropriate competent party before proceeding.

Need help identifying your product documents?

Send your order number, product label and a description of what you need.

This page is general guidance. The product-specific manufacturer's instructions, supporting evidence and project specification govern installation. Our online shop does not undertake installation, inspection, site surveys or certification of completed works.